Proper flashing and sealing of roof penetrations, conduit entries and flat-roof membranes where your solar system passes through, so the installation stays watertight.
From $390 (Per roof), including GST. Indicative starting price: the final fixed price is confirmed in writing after a site assessment.
SKU: BES-RSW-04
Brand: Blue Energy Solar
Pack size: Per roof
Form: Service
Categories: All Properties
Share it:
Every solar installation needs a path from the roof to the switchboard: cable entries, conduit penetrations and, on metal and flat roofs, fixings that pass through the roof surface. Done well, these points stay watertight for the life of the system. Done poorly, they are a common cause of leaks after installation, often showing up months later as a stained ceiling.
Waterproofing starts from $390 per roof. This is an indicative starting price; the final price depends on the roof type, the number of penetrations, membrane condition, the area to be treated and access.
What's included
Inspection of existing or planned roof penetrations, conduit entries and fixing points
Purpose-made flashings or boots for cable and conduit penetrations
Sealing with products suited to the roofing material and UV exposure
Membrane patching or reinforcement around fixings on flat roofs
Drainage checks so frames and rails do not block water flow
Photos of the completed waterproofing for your records
Why Blue Energy Solar
We treat waterproofing as part of the installation, not an afterthought. Our team plans cable routes that keep roof penetrations to a minimum and uses flashings suited to the roof rather than relying on sealant alone. Flat and low-pitch roofs on apartments, commercial buildings and modern homes get extra attention, because water that sits on a roof finds any weakness in a membrane. For existing systems installed by another installer, we can inspect and reseal leaking penetrations.
Recommended for
Owners of flat, low-pitch, membrane or metal roofs, and anyone adding solar where cables and fixings must pass through the roof.
Silicone alone is not a long-term waterproofing solution on a roof. UV exposure and heat cycles break it down over time, which is why proper flashings and compatible sealants matter.
Flat-roof membranes can carry manufacturer or builder warranties, and new penetrations may affect them, so tell us about any existing warranty.
A membrane in poor condition may need broader repair by a waterproofing specialist.
Strata buildings typically need owners corporation approval for roof penetrations.
Water can travel along rafters or sheets, so a visible drip is not always directly under its source.
Directions
1. Request a quote, or add waterproofing to your solar installation quote.
2. We inspect the roof, penetrations and any membrane areas.
3. We send a written quote listing each penetration and area to be treated.
4. Once accepted, we complete the waterproofing with flashings and compatible sealants.
5. We check drainage around the array and provide photos of the completed work.
Warnings
The price shown is an indicative starting price; the final fixed price is confirmed in writing after a site inspection and quote.
Work covers the penetrations and areas listed in the quote; wider roof or membrane defects are quoted separately.
Strata and commercial buildings need owners corporation or building owner approval before work starts.
Checking existing membrane or roof warranties before new penetrations are made is the owner's responsibility.
Water damage to ceilings, finishes or contents inside the building is not repaired under this service.
Frequently Asked Questions
Yes, including systems installed by another installer. We trace the likely source, which is often a cable entry, a cracked tile near a mounting bracket or a failed sealant joint, and quote the repair in writing. Where a leak comes from damaged roofing rather than the solar installation, we tell you so you can arrange the right trade.
Flat roofs need extra care because water sits on them. We favour mounting methods that keep penetrations to a minimum, such as ballasted frames where the structure and wind engineering allow, or use fixings with purpose-made flashings compatible with the membrane. Every penetration is sealed with compatible materials, and frames are positioned so water still drains freely.
It can, particularly on newer membrane roofs or metal roofs still under a manufacturer or builder warranty. Some warranties set conditions for penetrations or approved products. Check your documents before installation and tell us what they require; we plan fixings and flashings to suit where possible, and the builder's approval may be needed.
Correctly installed flashings and compatible sealants commonly last many years, but roofs move, and UV and heat take their toll on any sealant. We suggest having penetrations checked during routine system inspections, especially after major storms. Those checks should be done by trained people with safety equipment, never by climbing onto the roof yourself.
Delivery Options
Service area & scheduling
Where we work
Sydney and a radius of roughly 200 km: Newcastle, the Central Coast, Wollongong, the Southern Highlands, the Blue Mountains, Bathurst, Orange, Lithgow, Goulburn and the Canberra region.
Timing
Usually completed as part of your solar installation, or within 1-3 weeks of accepting the quote for an existing system.
How your request works
Send your request and our team contacts you to arrange the site assessment. You receive a written fixed-price quote before any work starts.
All electrical work is carried out by licensed electricians; solar and battery design and installation by SAA-accredited installers.
Blue Energy Solar is a New Energy Tech Approved Seller and holds $20 million public liability cover.